Error codes of air conditioners CHIGO (Chigo) - decoding and instructions

Error codes of air conditioners CHIGO (Chigo) - decoding and instructionsMost air conditioner models CHIGO equipped with a self-diagnosis option. If any malfunction is detected, the air conditioner stops and the error code of the Chigo air conditioner is immediately displayed, which is easy to find in the instructions.

To notify about errors, air conditioners use blinking diodes located on the front of the indoor module. When a breakdown of the air conditioner is detected, the bulbs begin to blink or glow continuously, which is also reflected in the instructions.

CHIGO air conditioner error codes

Chigo air conditioner errorDecoding
E0Power outage due to error
E1Overpressure protection too weak
E2Indoor temperature sensor defective
E3The temperature sensor of the external pipeline is faulty
E7The system is turned off due to a voltage drop in the network
E8Outdoor unit icing

Indoor unit error codes

DecodingRunning indicatorTimer indicatorChigo air conditioner error code
The function of the internal temperature sensor is broken1 time in 8 seconds+E2
Outdoor unit evaporator temperature sensor malfunction2 times every 8 seconds+E3
Anti-icing3 times every 8 seconds+E8
Drainage pump does not work4 times in 8 seconds+E9
Indoor unit fan does not work6 times every 8 seconds+E5
Outdoor unit check valve does not work7 times every 8 seconds+E7
Zero crossing error+3 times every 8 secondsE0
The temperature sensor of the internal evaporator does not work+4 times in 8 secondsE1
EEPROM failure+6 times every 8 secondsE6

Outdoor unit error codes

Decoding the error of the air conditioner CHIGORunning indicatorTimer indicatorChigo air conditioner error code
Outdoor temperature sensor does not work+Blinks once every 8 secondsE2
Outdoor evaporator temperature sensor does not work+Blinks 2 times every 8 secondsE3
Compressor current protection+Blinks 3 times every 8 secondsE7
The output temperature sensor does not work+Blinks 4 times every 8 secondsE1
Lost connection of outdoor and indoor units+Blinks 6 times every 8 secondsE6
Module protection+Blinks 7 times every 8 secondsE5
Decoding the error of the air conditioner CHIGOAir conditioner error code CHIGO indication on the board
DefrostingBlinks once every 1 second
Outdoor unit icing protectionBlinks once every 3 seconds
Malfunction of the room temperature sensorBlinks 2 times every 4 seconds
Malfunction of the temperature sensor on the evaporator of the indoor moduleBlinks 3 times every 5 seconds
Incorrect operation of the outdoor unitBlinks 4 times every 6 seconds
Frost protection for outdoor unitBlinks 5 times every 7 seconds
Pressure drop protectionBlinks 6 times every 8 seconds
Outdoor fan is malfunctioningBlinks 7 times every 9 seconds
Overheating protection activatedBlinks 8 times every 10 seconds
The operation of the drain pump or drainage branch is impairedBlinks 9 times every 11 seconds